Main technical parameters |
||||||||||||||||||
Mode |
WBE-LR2-49LA/B/C |
WBE-LR2-100LA/B/C |
WBE-LR2-150LA/B/C |
WBE-LR2-250LA/B/C |
WBE-LR2-450LA/B/C |
WBE-LR2-1000LA/B/C |
||||||||||||
Volume(L) |
49L |
100L |
150L |
250L |
450L |
1000L |
||||||||||||
Basket size WxDxH(mm) |
400×350×350 |
500×500×400 |
600×500×500 |
700×600×600 |
800×800×700 |
1000×1000×1000 |
||||||||||||
Outer size WxDxH(mm) |
1180x1850x1913 |
1280X1900X2215 |
1380x2000X2215 |
1480x2175X2215 |
1480x2376x2410 |
1780x2710X2876 |
||||||||||||
Basket temperature range |
150℃~ABC |
150℃~ABC |
150℃~ABC |
150℃~ABC |
150℃~ABC |
150℃~ABC |
||||||||||||
A -40 |
B -55 |
C-65 |
A -40 |
B -55 |
C-65 |
A -40 |
B -55 |
C-65 |
A -40 |
B -55 |
C-65 |
A -40 |
B -55 |
C-65 |
A -40 |
B -55 |
C-65 |
|
Overall power KW |
7.75 |
8.75 |
10.75 |
12.5 |
14 |
15.5 |
21.25 |
24.25 |
27.25 |
28 |
31 |
35.5 |
37.9 |
45.4 |
45.4 |
50 |
57.5 |
57.5 |
Tonnage of water tower RT |
Air cooling is not required |
5 |
Air cooling |
5 |
8 |
8 |
10 |
12 |
10 |
12 |
15 |
15 |
20 |
20 |
20 |
25 |
25 |
|
Water discharge m³/h |
/ |
/ |
2.35 |
/ |
3.9 |
4.68 |
6.24 |
7.8 |
9.36 |
7.8 |
9.36 |
11.7 |
11.7 |
15.6 |
15.6 |
15.6 |
19.5 |
19.5 |
Pipe diameter DN/mm |
/ |
/ |
40 |
/ |
40 |
40 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
65 |
65 |
65 |
65 |
65 |
Window size W*H(mm) |
W210*H300*2 |
W280*H350*2 |
W280*H350*2 |
W290*H420*2 |
W350*H500*2 |
W350*H500*2 |
||||||||||||
Noise(dB) |
≤72dB |
≤72dB |
≤72dB |
≤75dB |
≤75dB |
≤75dB |
||||||||||||
Heat storage temperature time |
RT~200℃ approximately take≤30min |
|||||||||||||||||
Storage temperature time |
A:+20~ -50℃ approximately take 35min B:+20~ -65℃ approximately take ≤45min C:+20~ -75℃ approximately take 55min |
|||||||||||||||||
High temperature impact range |
+60℃~ +150℃ |
|||||||||||||||||
Low temperature impact range |
A:-10℃~ -40℃ B:-10℃~ -55℃ C:-10℃~ -65℃ |
|||||||||||||||||
Temperature fluctuation |
≤±0.5℃ |
|||||||||||||||||
Temperature uniformity |
≤2.0℃ non-load |
|||||||||||||||||
Temperature deviation |
≤±2.0℃ non-load |
|||||||||||||||||
Basket conversion time |
5S |
|||||||||||||||||
Temperature recovery time |
≤ 5min |
|||||||||||||||||
High temperature exposure 15min/ low temperature exposure 15min |
||||||||||||||||||
Continuous testing without defrosting times |
1000 times (without defrosting) optional if required |
|||||||||||||||||
Operating ambient temperature |
Air cooling ambient temperature requirements 5~ +30℃/ Water cooling ambient temperature requirements +5~ +40℃ (water cooling requires a water tower or ice water machine) |
|||||||||||||||||
|
Test product mobile type, preheating zone, precooling zone two zone structure |
|||||||||||||||||
Weight (approx) (Kg) |
1000 |
1200 |
1600 |
1900 |
2500 |
3500 |
||||||||||||
Temperature-time resolution |
Temperature:0.01℃;Time: 0.01min。 |
|||||||||||||||||
Standard fittings |
insulated glass viewing window 1pcs, samples rack 2pcs, measuring hole diameter 50mm*1pcs, power cord, instruction manual. |
|||||||||||||||||
Power suply |
AC380V±10%,50Hz±1Three-phase four-wire + ground cable (3/N/PE), the ground resistance is < 4Ω |