It is used to test the degree of endurance of various materials under the continuous environment of extremely high temperature and extremely low temperature in an instant, so as to detect chemical changes or physical damage caused by thermal expansion and contraction of samples in the shortest time. Mainly used in semiconductor chips, scientific research institutions, quality inspection, new energy, optoelectronic communications, aerospace military, automotive industry, LCD display, medical and other science and technology industries.
Other name
High and low temperature (temperature) impact test chamber, three boxes (three slots) cold and hot impact test chamber, three boxes (three slots) high and low temperature impact test chamber, three boxes (three slots) temperature impact test chamber, high and low temperature impact test chamber, temperature impact test chamber。
Meet test criteria
Three-box test method: GJB 150.5-1986, MIL STD 883H, MIL STD 202G, IEC 60068-2-14, JIS C 60068-2-14, JASO D 014-4, EIA JED-2531A.。
Main technical parameters |
||||||||||||||||||
Model |
WBE-LR3-49LA/B/C |
WBE-LR3-100LA/B/C |
WBE-LR3-150LA/B/C |
WBE-LR3-250LA/B/C |
WBE-LR3-450LA/B/C |
WBE-LR3-1000LA/B/C |
||||||||||||
Volume(L) |
49L |
100L |
150L |
250L |
450L |
1000L |
||||||||||||
Inner sizeWxDxH(mm) |
350×350×400 |
500×400×500 |
600×500×500 |
700×600×600 |
800×800×700 |
1000×1000×1000 |
||||||||||||
Outer size WxDxH(mm)
|
Water cooling 1370X1640X1740 Air cooling1470X1640X1740 |
Water cooling1520X1690X1840 Air cooling1620X1690X1840 |
1620x1840X1820 |
1720x2100X1820 |
1820x2200x2150 |
2120x2600x2318 |
||||||||||||
Test temperature range ℃ |
150℃~ABC |
150℃~ABC |
150℃~ABC |
150℃~ABC |
150℃~ABC |
150℃~ABC |
||||||||||||
|
A -40 |
B -55 |
C-65 |
A -40 |
B -55 |
C-65 |
A -40 |
B -55 |
C-65 |
A -40 |
B -55 |
C-65 |
A -40 |
B -55 |
C-65 |
A -40 |
B -55 |
C-65 |
Operating powerKW |
7.75 |
8.75 |
10.75 |
12.5 |
14 |
15.5 |
21.25 |
24.25 |
27.25 |
28 |
31 |
35.5 |
37.9 |
45.4 |
45.4 |
50 |
57.5 |
57.5 |
Tonnage of water tower RT |
Air cooling is not required |
5 |
Air cooling |
5 |
8 |
8 |
10 |
12 |
10 |
12 |
15 |
15 |
20 |
20 |
20 |
25 |
25 |
|
Water discharge m³/h |
/ |
/ |
2.35 |
/ |
3.9 |
4.68 |
6.24 |
7.8 |
9.36 |
7.8 |
9.36 |
11.7 |
11.7 |
15.6 |
15.6 |
15.6 |
19.5 |
19.5 |
Pipe diameterDN/mm |
/ |
/ |
40 |
/ |
40 |
40 |
50 |
50 |
50 |
50 |
50 |
50 |
50 |
65 |
65 |
65 |
65 |
65 |
Window size W*H(mm)Optional |
No |
W280*H350 |
W280*H350 |
W290*H420 |
W350*H500 |
W350*H500 |
||||||||||||
Equipment noise(dB) |
≤72 |
≤72 |
≤72 |
≤75 |
≤75 |
≤75dB |
||||||||||||
Heat storage temperature time |
RT~200℃ ≤30min |
|||||||||||||||||
Cold storage temperature time |
A:+20~ -55℃ approximately 40min B:+20~ -70℃ ≤50min C:+20~ -75℃ approximately 55min |
|||||||||||||||||
High temperature impact range |
+60℃~ +150℃ |
|||||||||||||||||
Low temperature impact range |
A:-10℃~ -40℃ B:-10℃~ -55℃ C:-10℃~ -65℃ |
|||||||||||||||||
Temperature fluctuation |
≤±0.5℃ |
|||||||||||||||||
Temperature uniformity |
≤2.0℃ non-load |
|||||||||||||||||
Temperature deviation |
≤±2.0℃ non-load |
|||||||||||||||||
Damper transition time |
5S |
|||||||||||||||||
Temperature recovery time |
≤ 5min |
|||||||||||||||||
|
High temperature exposure 15min/ low temperature exposure 15min |
|||||||||||||||||
Test times |
1000times Without defrosting during testing (optional) |
|||||||||||||||||
ambient temperature |
Air cooling ambient temperature requirements 5~ +30℃/ Water cooling ambient temperature requirements +5~ +40℃ (water cooling requires a water tower or ice water machine) |
|||||||||||||||||
System structure |
Three box structure of non-moving independent test area, preheating area and precooling area |
|||||||||||||||||
Weight(about)(Kg) |
900 |
1100 |
1500 |
1900 |
2400 |
3300 |
||||||||||||
Temperature-time resolution |
Temperature:0.01℃;Time: 0.01min |
|||||||||||||||||
Standard fittings |
insulated glass viewing window 1pcs, samples rack 2pcs, measuring hole diameter 50mm*1pcs, power cord, instruction manual. |
|||||||||||||||||
Power supply |
AC380V±10%,50Hz±1Three-phase four-wire + ground cable (3/N/PE), the ground resistance is < 4Ω |