Products

3-zone temperature impact test chamber

Product description

It is used to test the degree of endurance of various materials under the continuous environment of extremely high temperature and extremely low temperature in an instant, so as to detect chemical changes or physical damage caused by thermal expansion and contraction of samples in the shortest time. Mainly used in semiconductor chips, scientific research institutions, quality inspection, new energy, optoelectronic communications, aerospace military, automotive industry, LCD display, medical and other science and technology industries.

Other name
High and low temperature (temperature) impact test chamber, three boxes (three slots) cold and hot impact test chamber, three boxes (three slots) high and low temperature impact test chamber, three boxes (three slots) temperature impact test chamber, high and low temperature impact test chamber, temperature impact test chamber。

 

Meet test criteria
Three-box test method: GJB 150.5-1986, MIL STD 883H, MIL STD 202G, IEC 60068-2-14, JIS C 60068-2-14, JASO D 014-4, EIA JED-2531A.。

Product features
01
Adopt the most cutting-edge electronic expansion valve technology;
02
Energy saving about 30%;
03
Continuous impact 1000 times without defrosting (optional);
04
Evaporator is not easy to frost;
05
Linear model is more convenient to realize;
06
Stable and fast temperature, better uniformity control;
07
The compressor is not easy to frost, the whole machine life is 1/3 longer than the traditional technology;
08
Non-standard design is more convenient;
09
ESS box load heating automatic adaptation;
10
Three boxes can test impact room temperature;
11
There are three parts: high temperature area, low temperature area and test area. The test product is placed in the test area, and the temperature of the high temperature area or low temperature area is rushed into the test area for impact. The test product is static; Convenient power test and impact room temperature test.
Technical specifications

Main technical parameters

Model

WBE-LR3-49LA/B/C

WBE-LR3-100LA/B/C

WBE-LR3-150LA/B/C

WBE-LR3-250LA/B/C

WBE-LR3-450LA/B/C

WBE-LR3-1000LA/B/C

Volume(L)

49L

100L

150L

250L

450L

1000L

Inner sizeWxDxH(mm)

350×350×400

500×400×500

600×500×500

700×600×600

800×800×700

1000×1000×1000

Outer size WxDxH(mm)

 

Water cooling 1370X1640X1740

Air cooling1470X1640X1740

Water cooling1520X1690X1840

Air cooling1620X1690X1840

1620x1840X1820

1720x2100X1820

1820x2200x2150

2120x2600x2318

Test temperature range ℃

150℃~ABC

150℃~ABC

150℃~ABC

150℃~ABC

150℃~ABC

150℃~ABC

 

A -40

B -55

C-65

A -40

B -55

C-65

A -40

B -55

C-65

A -40

B -55

C-65

A -40

B -55

C-65

A -40

B -55

C-65

Operating powerKW

7.75

8.75

10.75

12.5

14

15.5

21.25

24.25

27.25

28

31

35.5

37.9

45.4

45.4

50

57.5

57.5

Tonnage of water tower RT

Air cooling is not required

5

Air cooling

5

8

8

10

12

10

12

15

15

20

20

20

25

25

Water discharge m³/h

/

/

2.35

/

3.9

4.68

6.24

7.8

9.36

7.8

9.36

11.7

11.7

15.6

15.6

15.6

19.5

19.5

Pipe diameterDN/mm

/

/

40

/

40

40

50

50

50

50

50

50

50

65

65

65

65

65

Window size W*H(mm)Optional

No

W280*H350

W280*H350

W290*H420

W350*H500

W350*H500

Equipment noise(dB)

≤72

≤72

≤72

≤75

≤75

≤75dB

Heat storage temperature time

RT~200℃ ≤30min

Cold storage temperature time

A:+20~ -55℃ approximately 40min     B:+20~ -70℃ ≤50min    C:+20~ -75℃ approximately 55min

High temperature impact range

+60℃~ +150℃

Low temperature impact range

A:-10℃~ -40℃            B:-10℃~ -55℃             C:-10℃~ -65℃

Temperature fluctuation

≤±0.5℃

Temperature uniformity

≤2.0℃ non-load

Temperature deviation

≤±2.0℃ non-load

Damper transition time

5S

Temperature recovery time

≤ 5min

 

High temperature exposure 15min/ low temperature exposure 15min

Test times

1000times Without defrosting during testing (optional)

ambient temperature

Air cooling ambient temperature requirements 5~ +30℃/ Water cooling ambient temperature requirements +5~ +40℃ (water cooling requires a water tower or ice water machine)

System structure

Three box structure of non-moving independent test area, preheating area and precooling area

Weight(about)(Kg)

900

1100

1500

1900

2400

3300

Temperature-time resolution

Temperature:0.01℃;Time: 0.01min

Standard fittings

insulated glass viewing window 1pcs, samples rack 2pcs, measuring hole diameter 50mm*1pcs, power cord, instruction manual.

Power supply

AC380V±10%,50Hz±1Three-phase four-wire + ground cable (3/N/PE), the ground resistance is < 4Ω