It is used to detect the performance of products under rapid temperature changes and extreme temperature conditions. Mainly used in semiconductor chips, scientific research institutions, quality inspection, new energy, optoelectronic communications, aerospace , automotive industry, LCD display, medical and other science and technology industries.
Meet test criteria
1. GB/T 2423.1 Low temperature test method
2.GJB 150.3 high temperature test
3.GB/T 2423.2 high temperature test method
4.GJB 150.4 low temperature test
5. GB/T2423.34 humid heat cycle test method
6. GJB 150.9 damp heat test
7.IEC60068-2 temperature and humidity test method
8. MIL-STD-202G-103B humidity test
Technical parameters: |
|||||||
name |
Rapid temperature change test chamber |
||||||
Model Number |
WBE-KSH-150L |
WBE-KSH-225L |
WBE-KSH-512L |
WBE-KSH-1000L |
WBE-KSH-2400L |
WBE-KSH-3400L |
WBE-KSH-4600L |
Volume(L) |
150 |
225 |
512 |
1000 |
2400 |
3400 |
4600 |
Test room dimensions (WxDxH)(mm) |
500x500x600 |
600x500x750 |
800x800x800 |
1100x900x1100 |
1300x1400x1300 |
1500x1500x1500 |
1800x1500x1700 |
Window (WxH) (mm) |
210x300 |
280x350 |
360x510 |
360x510 |
360x510 |
360x510*2 |
360x510*2 |
Linear temperature range and linear temperature rate /min |
-40~125 ° C (AX linear 2 ° C /5 ° C /10 ° C /15 ° C /20 ° C /25 ° C; AF Nonlinear 2℃/5℃/10℃/15℃/20℃/25℃) |
||||||
|
AX2、AX5、AX10、AX15、AX20、AX25 , AF2、AF5、AF10、AF15、AF20、AF25; For example, AX15: A linear range -40~125 ° C, X linear 15 ° C. AF15: A nonlinear range: -40~125℃, F nonlinear 15℃, |
||||||
Nonlinear (average) temperature range and nonlinear (average) temperature rate /min |
-55~125℃ (CX linear 2℃/5℃/10℃/15℃; CF nonlinear 2℃/5℃/10℃/15℃/20℃/25℃) |
||||||
|
CX2、CX5、CX10、CX15,CF2、CF5、CF10、CF15、CF20、CF25; For example, CX10: C linear range -55~125 ° C,X linear range 10 ° C. CF10: C nonlinear range: -55~125 ° C,F nonlinear 10 ° C. |
||||||
Environmental requirement |
Air cooling ambient temperature requirements +5 to +30°C/Water cooling ambient temperature requirements +5 to +40°C (Water cooling requires a water tower or water cooler). |
||||||
Temperature performance index: |
|||||||
Temperature range |
-70℃~+150℃ |
||||||
Temperature uniformity |
≤2.0℃。 |
||||||
Temperature deviation |
≤±2.0℃。 |
||||||
Temperature fluctuation |
≤±0.5℃ (≤±0.5℃, according to GB/T5170-1996). |
||||||
Power source |
AC380V±10%,50Hz±1 Three-phase four-wire + ground cable (3/N/PE), grounding resistance less than 4Ω. |
||||||
Standard configuration |
observation window (double hollow tempered conductive glass) 1pcs; Test hole Φ50/Φ100mm (on the left) 1pcs; Sample rack 2 layers 1pcs; camera light (LED light strip) 1pcs in the box; small casters 4pcs; power cable 1pcs. |