Rapid temperature change test chamber KSH-100

Product description

It is used to detect the performance of products under rapid temperature changes and extreme temperature conditions. Mainly used in semiconductor chips, scientific research institutions, quality inspection, new energy, optoelectronic communications, aerospace , automotive industry, LCD display, medical and other science and technology industries.

 

Meet test criteria

1. GB/T 2423.1 Low temperature test method

2.GJB 150.3 high temperature test

3.GB/T 2423.2 high temperature test method

4.GJB 150.4 low temperature test

5. GB/T2423.34 humid heat cycle test method

6. GJB 150.9 damp heat test

7.IEC60068-2 temperature and humidity test method

8. MIL-STD-202G-103B humidity test

Technical specifications

Technical parameters:

name

Rapid temperature change test chamber

Model Number

WBE-KSH-150L

WBE-KSH-225L

WBE-KSH-512L

WBE-KSH-1000L

WBE-KSH-2400L

WBE-KSH-3400L

WBE-KSH-4600L

Volume(L)

150

225

512

1000

2400

3400

4600

Test room dimensions (WxDxH)(mm)

500x500x600

600x500x750

800x800x800

1100x900x1100

1300x1400x1300

1500x1500x1500

1800x1500x1700

Window (WxH) (mm)

210x300

280x350

360x510

360x510

360x510

360x510*2

360x510*2

Linear temperature range and linear temperature rate /min

-40~125 ° C (AX linear 2 ° C /5 ° C /10 ° C /15 ° C /20 ° C /25 ° C; AF Nonlinear 2℃/5℃/10℃/15℃/20℃/25℃)

 

AX2、AX5、AX10、AX15、AX20、AX25 , AF2、AF5、AF10、AF15、AF20、AF25;

For example, AX15: A linear range -40~125 ° C, X linear 15 ° C. AF15: A nonlinear range: -40~125℃, F nonlinear 15℃,

Nonlinear (average) temperature range and nonlinear (average) temperature rate /min

-55~125℃ (CX linear 2℃/5℃/10℃/15℃; CF nonlinear 2℃/5℃/10℃/15℃/20℃/25℃)

 

CX2、CX5、CX10、CX15,CF2、CF5、CF10、CF15、CF20、CF25;

For example, CX10: C linear range -55~125 ° C,X linear range 10 ° C. CF10: C nonlinear range: -55~125 ° C,F nonlinear 10 ° C.

Environmental requirement

Air cooling ambient temperature requirements +5 to +30°C/Water cooling ambient temperature requirements +5 to +40°C (Water cooling requires a water tower or water cooler).

Temperature performance index:

Temperature range

-70℃~+150℃    

Temperature uniformity

≤2.0℃。

Temperature deviation

≤±2.0℃。

Temperature fluctuation

≤±0.5℃ (≤±0.5℃, according to GB/T5170-1996).

Power source

AC380V±10%,50Hz±1 Three-phase four-wire + ground cable (3/N/PE), grounding resistance less than 4Ω.

Standard configuration

observation window (double hollow tempered conductive glass) 1pcs; Test hole Φ50/Φ100mm (on the left) 1pcs; Sample rack 2 layers 1pcs; camera light (LED light strip) 1pcs in the box; small casters 4pcs; power cable 1pcs.