Three comprehensive high and low temperature vibration test chamber combined with temperature, humidity, vibration functions in one of the three functions of the test chamber, with rapid temperature change rate, to provide temperature, humidity and vibration of the comprehensive test environment functions. Applicable to aerospace products, information electronic instruments, materials, electrical, electronic products, all kinds of electronic components in a comprehensive harsh environment to test their performance indicators。
Meet test criteria:
1.Method for parameter verification of environmental test equipment for electrical and electronic products (temperature test equipment)
2.GB2423.1 Basic Environmental Test Rules for Electrical and electronic Products (Test A low temperature test method)
3.GB2423.2 Basic Environmental Test Rules for Electrical and electronic Products (Test B High temperature test method)
4.GB/T2423.3 Basic Environmental test Procedure for electrical and electronic products (wet heat test method)
5.GJB150.3-86 Environmental Test method for testing Equipment (High temperature test)
6.GB/T28046.4 ISO16750-4, GMW3172, VW80101, GB/T10485, etc.
1.Main Technical parameter: |
||||||||
Name |
Temperature, Humidity and Vibration test chamber |
|||||||
Model |
WBE-SZH512L |
WBE-SZH1000L |
WBE-SZH1700L |
WBE-SZH2700L |
||||
Volume(L) |
512L |
1000L |
1700L |
2700L |
||||
Test room size(WxDxH)(mm) |
800*800*800 |
1000*1000*1000 |
1200*1200*1200 |
1400*1400*1200 |
||||
Outer size(WxDxH)(mm) |
1000*2415*1100 |
1200*2615*1320 |
1400*2965*1400 |
1600*3132*1500 |
||||
Lift range (mm) |
Customized according to the selected vibration table |
|||||||
Lift weight and power |
According to the selected vibration table configuration |
|||||||
Window(WxH)(mm) |
360x510 |
360x510 |
360x510 |
360x510 |
||||
Minimum low temperature(℃) |
A-40 |
D-70 |
A-40 |
D-70 |
A-40 |
D-70 |
A-40 |
D-70 |
Noise(dB) |
≤72dB |
≤72dB |
≤75dB |
≤75dB |
||||
Power supply (KW) (including lift) (excluding vibration table) |
5.5KW |
7.5KW |
9.5 |
10.5 |
11.5 |
13.5 |
15 |
18 |
Voltage AC(V) |
AC380V±10%,50Hz±1Three-phase four-wire + ground cable (3/N/PE), the ground resistance is less than4Ω |
|||||||
Weight (kg) (including lift) (excluding vibration table) |
650KG |
1100KG |
1400KG |
1700KG |
||||
Environmental requirement |
Air cooling ambient temperature requirements +5~ +30℃/ Water cooling ambient temperature requirements +5~ +40℃ (Water cooling requires a water tower or chiller) |
|||||||
Air speed |
≤1.7m/s。 |
|||||||
2.Temperature performance index: |
||||||||
Temperature range |
A:-40℃~+150℃, D:-70℃~+150℃, pls select Nature:A -40℃~+150℃。 |
|||||||
Temperature uniformity |
≤1.0℃(-40℃~+100℃/-70℃~+100℃); ≤1.5℃(-40℃~+150℃/-70℃~+150℃)。 |
|||||||
Temperature deviation |
≤±1.0℃(-40℃~+100℃/-70℃~+100℃); ≤±1.5℃(-40℃~+150℃/-70℃~+150℃)。 |
|||||||
Temperature fluctuation |
≤±0.3℃ (≤±0.5℃,Base on GB/T5170-1996 Standard) |
|||||||
Heating rate |
-40℃ (-70℃) →+150℃ heating rate: 1~6℃/min nonlinear (average) adjustable; +25℃→+150℃ heating rate: 1~5℃/min nonlinear (average) adjustable; +25℃→+150℃ heating rate: 0.1~3℃/min linear slope adjustable; (Temperature rate 4 ~ 25℃/ min Linear/nonlinear for special conditions need to be customized) |
|||||||
Cooling rate |
+150℃→-40℃ Cooling rate: 1~3℃/min nonlinear (average) adjustable; +150℃→-70℃ Cooling rate: 1~2.5℃/min nonlinear (average) adjustable; +25℃→-40℃ (-70℃) Cooling rate: 1~1.7℃/min nonlinear (average) adjustable; +25℃→-40℃ (-70℃) Cooling rate: 1℃/min linear slope adjustable; (Temperature rate 2 ~ 25℃/ min linear/nonlinear for special conditions need to be customized) |
|||||||
3.Humidity performance index: |
||||||||
Temperature range |
+10℃~+95℃。 |
|||||||
Humidity range |
10%RH~98%RH(5%~98%R.H;Customized for special conditions) |
|||||||
Humidity uniformity |
≤3.0%RH。 |
|||||||
Humidity deviation |
+2.0%RH~-3.0%RH(±3.0%RH Base on GB/T 2423.3-2008 Standard) |
|||||||
Humidity fluctuation |
≤±2.0%RH。 |
|||||||
Temperature and humidity all test points |
For details, see 2.2 Temperature and Humidity Control Capability Diagram. |
|||||||
Time resolution of temperature and humidity |
Temperature:0.01℃;Humidity: 0.1%;Time: 0.01min |
|||||||
Standard configuration |
observation window (double-layer hollow tempered conductive glass) 1pcs, test holes Φ100mm (located on the left and right sides), 2 layers of sample rack 1pcs, (LED light) 1pcs in the box, water supply box 1pcs, small casters 4pcs, power cord1pcs |